<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.conservapedia.com/index.php?action=history&amp;feed=atom&amp;title=House_wiring</id>
	<title>House wiring - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://www.conservapedia.com/index.php?action=history&amp;feed=atom&amp;title=House_wiring"/>
	<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;action=history"/>
	<updated>2026-10-06T03:26:00Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.35.14</generator>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=1256995&amp;oldid=prev</id>
		<title>DavidB4-bot: clean up &amp; uniformity</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=1256995&amp;oldid=prev"/>
		<updated>2016-07-13T14:08:03Z</updated>

		<summary type="html">&lt;p&gt;clean up &amp;amp; uniformity&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 14:08, July 13, 2016&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l13&quot; &gt;Line 13:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;European countries use a 230V, &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;50Hz &lt;/del&gt;standard for domestic power. The power cable entering a domestic property typically passes first through a tamper-evident high-current fuse. This serves both as a last-resort isolator, and a means to disconnect power from the consumer unit for maintenance. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is typically legally defined as the legal demarcation point between utility company and property holder ownership and responsibility.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;European countries use a 230V, &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;50&amp;amp;nbsp;Hz &lt;/ins&gt;standard for domestic power. The power cable entering a domestic property typically passes first through a tamper-evident high-current fuse. This serves both as a last-resort isolator, and a means to disconnect power from the consumer unit for maintenance. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is typically legally defined as the legal demarcation point between utility company and property holder ownership and responsibility.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Typically, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which automatically isolates in the event of a fault. It may be a physically separate box, or a component within a consumer unit.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Typically, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which automatically isolates in the event of a fault. It may be a physically separate box, or a component within a consumer unit.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l19&quot; &gt;Line 19:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 19:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and typically include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and typically include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Also&lt;/del&gt;==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;also&lt;/ins&gt;==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;category&lt;/del&gt;:&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;construction&lt;/del&gt;]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Category&lt;/ins&gt;:&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Construction&lt;/ins&gt;]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>DavidB4-bot</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=390516&amp;oldid=prev</id>
		<title>NathanG: sp &quot;typically&quot;, &quot;isolator&quot;, &quot;maintenance&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=390516&amp;oldid=prev"/>
		<updated>2008-02-18T20:59:20Z</updated>

		<summary type="html">&lt;p&gt;sp &amp;quot;typically&amp;quot;, &amp;quot;isolator&amp;quot;, &amp;quot;maintenance&amp;quot;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 20:59, February 18, 2008&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l13&quot; &gt;Line 13:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;European countries use a 230V, 50Hz standard for domestic power. The power cable entering a domestic property &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;typicially &lt;/del&gt;passes first through a tamper-evident high-current fuse. This serves both as a last-resort &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;isloator&lt;/del&gt;, and a means to disconnect power from the consumer unit for &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;maintinance&lt;/del&gt;. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;typicially &lt;/del&gt;legally defined as the legal &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;demarkation &lt;/del&gt;point between utility company and &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;propertyholder &lt;/del&gt;ownership and responsibility.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;European countries use a 230V, 50Hz standard for domestic power. The power cable entering a domestic property &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;typically &lt;/ins&gt;passes first through a tamper-evident high-current fuse. This serves both as a last-resort &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;isolator&lt;/ins&gt;, and a means to disconnect power from the consumer unit for &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;maintenance&lt;/ins&gt;. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;typically &lt;/ins&gt;legally defined as the legal &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;demarcation &lt;/ins&gt;point between utility company and &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;property holder &lt;/ins&gt;ownership and responsibility.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Typicially&lt;/del&gt;, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;automaticially &lt;/del&gt;isolates in the event of a fault. It may be a physically &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;seperate &lt;/del&gt;box, or a component within a consumer unit.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Typically&lt;/ins&gt;, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;automatically &lt;/ins&gt;isolates in the event of a fault. It may be a physically &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;separate &lt;/ins&gt;box, or a component within a consumer unit.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;typicially &lt;/del&gt;include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;typically &lt;/ins&gt;include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See Also==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See Also==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>NathanG</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=236479&amp;oldid=prev</id>
		<title>Aziraphale: categorize</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=236479&amp;oldid=prev"/>
		<updated>2007-07-16T23:34:55Z</updated>

		<summary type="html">&lt;p&gt;categorize&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 23:34, July 16, 2007&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l22&quot; &gt;Line 22:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 22:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[category:construction]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Aziraphale</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168251&amp;oldid=prev</id>
		<title>Ed Poor: electricians</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168251&amp;oldid=prev"/>
		<updated>2007-05-19T13:45:06Z</updated>

		<summary type="html">&lt;p&gt;&lt;a href=&quot;/index.php?title=Electrician&amp;amp;action=edit&amp;amp;redlink=1&quot; class=&quot;new&quot; title=&quot;Electrician (page does not exist)&quot;&gt;electricians&lt;/a&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:45, May 19, 2007&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot; &gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''House wiring''' refers to the various electrical circuits in stalled in a home to enable the use of electrical appliances.  The trained professionals who install and service these systems are called &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;electricians&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''House wiring''' refers to the various electrical circuits in stalled in a home to enable the use of electrical appliances.  The trained professionals who install and service these systems are called &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;[[electrician]]s&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== United States ==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== United States ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Ed Poor</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168250&amp;oldid=prev</id>
		<title>Ed Poor: spell check - 2 errors corrected</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168250&amp;oldid=prev"/>
		<updated>2007-05-19T13:44:38Z</updated>

		<summary type="html">&lt;p&gt;spell check - 2 errors corrected&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:44, May 19, 2007&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot; &gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;It starts with a heavy [[American Wire Gauge|gauge]] [[wire]] &amp;quot;drop&amp;quot; from a nearby [[public utility]] pole (or buried wires in some neighborhoods), which first connects to a [[electric meter|meter]] to measure electrical use for billing purposes.  This is in turn connected with heavy wire to a main service panel, where there will first be a main [[circuit breaker]].  The main breaker acts more as a switch than as a circuit protection device, and allows the de-energization of the wiring in the building so it can be worked on safely.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;It starts with a heavy [[American Wire Gauge|gauge]] [[wire]] &amp;quot;drop&amp;quot; from a nearby [[public utility]] pole (or buried wires in some neighborhoods), which first connects to a [[electric meter|meter]] to measure electrical use for billing purposes.  This is in turn connected with heavy wire to a main service panel, where there will first be a main [[circuit breaker]].  The main breaker acts more as a switch than as a circuit protection device, and allows the de-energization of the wiring in the building so it can be worked on safely.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The main service panel contains 1, 2, or 3 metal &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;busses &lt;/del&gt;to distribute the power to smaller circuit breakers, and ground and neutral lug bars.  The ground bar is wired to a metal rod driven into the ground nearby.  The individual circuit breakers then feed smaller wires that run to various places in the building.  The breakers are sized to &amp;quot;protect&amp;quot; the gauge of wire used - for instance, in most modern house wiring, the typical circuit uses a 20 amp breaker and is run with 12 gauge wire.  These 20 amp circuits will provide power to all the outlets and switched lighting in the house. The user should be careful not to overload these circuits, since a high [[current]] device (such as a hair dryer) could be plugged into each outlet, far exceeding the capacity of the breaker, and tripping it.  Usually modern wiring systems distribute the circuits in such a way as to make this less likely.  &lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The main service panel contains 1, 2, or 3 metal &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;buses &lt;/ins&gt;to distribute the power to smaller circuit breakers, and ground and neutral lug bars.  The ground bar is wired to a metal rod driven into the ground nearby.  The individual circuit breakers then feed smaller wires that run to various places in the building.  The breakers are sized to &amp;quot;protect&amp;quot; the gauge of wire used - for instance, in most modern house wiring, the typical circuit uses a 20 amp breaker and is run with 12 gauge wire.  These 20 amp circuits will provide power to all the outlets and switched lighting in the house. The user should be careful not to overload these circuits, since a high [[current]] device (such as a hair dryer) could be plugged into each outlet, far exceeding the capacity of the breaker, and tripping it.  Usually modern wiring systems distribute the circuits in such a way as to make this less likely.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Some [[appliance]]s have dedicated circuits, often with higher amperage breakers and heavier wire.  Typical examples are electric clothes dryers, stoves, private well pumps, and air conditioning.  A few appliances, while not needing higher current circuits, also require dedicated breakers, such as dishwashers.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Some [[appliance]]s have dedicated circuits, often with higher amperage breakers and heavier wire.  Typical examples are electric clothes dryers, stoves, private well pumps, and air conditioning.  A few appliances, while not needing higher current circuits, also require dedicated breakers, such as dishwashers.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Older systems are still found in use where [[fuse]]s take the place of circuit breakers.  These usually do not allow sufficient overall current to provide for the array of modern appliances we now &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;tke &lt;/del&gt;for granted, and so are upgraded as soon as the homeowner can afford it.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Older systems are still found in use where [[fuse]]s take the place of circuit breakers.  These usually do not allow sufficient overall current to provide for the array of modern appliances we now &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;take &lt;/ins&gt;for granted, and so are upgraded as soon as the homeowner can afford it.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Europe==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Ed Poor</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168241&amp;oldid=prev</id>
		<title>BornAgainBrit: Europe exists too.</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=168241&amp;oldid=prev"/>
		<updated>2007-05-19T13:41:06Z</updated>

		<summary type="html">&lt;p&gt;Europe exists too.&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:41, May 19, 2007&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l10&quot; &gt;Line 10:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 10:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Older systems are still found in use where [[fuse]]s take the place of circuit breakers.  These usually do not allow sufficient overall current to provide for the array of modern appliances we now tke for granted, and so are upgraded as soon as the homeowner can afford it.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Older systems are still found in use where [[fuse]]s take the place of circuit breakers.  These usually do not allow sufficient overall current to provide for the array of modern appliances we now tke for granted, and so are upgraded as soon as the homeowner can afford it.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==Europe==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;European countries use a 230V, 50Hz standard for domestic power. The power cable entering a domestic property typicially passes first through a tamper-evident high-current fuse. This serves both as a last-resort isloator, and a means to disconnect power from the consumer unit for maintinance. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is typicially legally defined as the legal demarkation point between utility company and propertyholder ownership and responsibility.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Typicially, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which automaticially isolates in the event of a fault. It may be a physically seperate box, or a component within a consumer unit.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and typicially include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See Also==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==See Also==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Building trades]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>BornAgainBrit</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=155324&amp;oldid=prev</id>
		<title>BornAgainBrit: Its quite different for us euros, so I just clarified this article only describes US standards.</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=155324&amp;oldid=prev"/>
		<updated>2007-05-11T12:59:01Z</updated>

		<summary type="html">&lt;p&gt;Its quite different for us euros, so I just clarified this article only describes US standards.&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left diff-editfont-monospace&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 12:59, May 11, 2007&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot; &gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''House wiring''' refers to the various electrical circuits in stalled in a home to enable the use of electrical appliances.  The trained professionals who install and service these systems are called electricians.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;'''House wiring''' refers to the various electrical circuits in stalled in a home to enable the use of electrical appliances.  The trained professionals who install and service these systems are called electricians.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt; &lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== United States ==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;It starts with a heavy [[American Wire Gauge|gauge]] [[wire]] &amp;quot;drop&amp;quot; from a nearby [[public utility]] pole (or buried wires in some neighborhoods), which first connects to a [[electric meter|meter]] to measure electrical use for billing purposes.  This is in turn connected with heavy wire to a main service panel, where there will first be a main [[circuit breaker]].  The main breaker acts more as a switch than as a circuit protection device, and allows the de-energization of the wiring in the building so it can be worked on safely.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt; &lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;It starts with a heavy [[American Wire Gauge|gauge]] [[wire]] &amp;quot;drop&amp;quot; from a nearby [[public utility]] pole (or buried wires in some neighborhoods), which first connects to a [[electric meter|meter]] to measure electrical use for billing purposes.  This is in turn connected with heavy wire to a main service panel, where there will first be a main [[circuit breaker]].  The main breaker acts more as a switch than as a circuit protection device, and allows the de-energization of the wiring in the building so it can be worked on safely.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>BornAgainBrit</name></author>
	</entry>
	<entry>
		<id>https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=115378&amp;oldid=prev</id>
		<title>Human: creation</title>
		<link rel="alternate" type="text/html" href="https://www.conservapedia.com/index.php?title=House_wiring&amp;diff=115378&amp;oldid=prev"/>
		<updated>2007-04-18T19:31:22Z</updated>

		<summary type="html">&lt;p&gt;creation&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;'''House wiring''' refers to the various electrical circuits in stalled in a home to enable the use of electrical appliances.  The trained professionals who install and service these systems are called electricians.&lt;br /&gt;
&lt;br /&gt;
It starts with a heavy [[American Wire Gauge|gauge]] [[wire]] &amp;quot;drop&amp;quot; from a nearby [[public utility]] pole (or buried wires in some neighborhoods), which first connects to a [[electric meter|meter]] to measure electrical use for billing purposes.  This is in turn connected with heavy wire to a main service panel, where there will first be a main [[circuit breaker]].  The main breaker acts more as a switch than as a circuit protection device, and allows the de-energization of the wiring in the building so it can be worked on safely.&lt;br /&gt;
&lt;br /&gt;
The main service panel contains 1, 2, or 3 metal busses to distribute the power to smaller circuit breakers, and ground and neutral lug bars.  The ground bar is wired to a metal rod driven into the ground nearby.  The individual circuit breakers then feed smaller wires that run to various places in the building.  The breakers are sized to &amp;quot;protect&amp;quot; the gauge of wire used - for instance, in most modern house wiring, the typical circuit uses a 20 amp breaker and is run with 12 gauge wire.  These 20 amp circuits will provide power to all the outlets and switched lighting in the house. The user should be careful not to overload these circuits, since a high [[current]] device (such as a hair dryer) could be plugged into each outlet, far exceeding the capacity of the breaker, and tripping it.  Usually modern wiring systems distribute the circuits in such a way as to make this less likely. &lt;br /&gt;
&lt;br /&gt;
Some [[appliance]]s have dedicated circuits, often with higher amperage breakers and heavier wire.  Typical examples are electric clothes dryers, stoves, private well pumps, and air conditioning.  A few appliances, while not needing higher current circuits, also require dedicated breakers, such as dishwashers.&lt;br /&gt;
&lt;br /&gt;
Older systems are still found in use where [[fuse]]s take the place of circuit breakers.  These usually do not allow sufficient overall current to provide for the array of modern appliances we now tke for granted, and so are upgraded as soon as the homeowner can afford it.&lt;br /&gt;
&lt;br /&gt;
==See Also==&lt;br /&gt;
&lt;br /&gt;
[[Building trades]]&lt;/div&gt;</summary>
		<author><name>Human</name></author>
	</entry>
</feed>